Filters
Question type

Study Flashcards

The positive temperature coefficient resistor start device is a type of ____.


A) capacitor
B) variable resistor
C) switching device
D) diode

E) None of the above
F) C) and D)

Correct Answer

verifed

verified

When a general duty split-phase motor reaches approximately 75% of its operating speed, the start winding is de-energized by a ____.


A) circuit board
B) capacitor
C) centrifugal switch
D) dual voltage switch

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

The windings of the relay coil in a current relay has very low resistance. Why?

Correct Answer

verifed

verified

It would drop too mu...

View Answer

A current magnetic relay opens and closes its contacts based on the ____.


A) current in the start winding
B) voltage across the start winding
C) voltage across the run winding
D) current in the run winding

E) C) and D)
F) A) and D)

Correct Answer

verifed

verified

The microfarad rating of the run capacitor is much lower than that of the start capacitor for any given motor application.

A) True
B) False

Correct Answer

verifed

verified

Capacitors wired in series with the starting winding provide a(n) ____.


A) longer starting time
B) greater starting torque
C) aid in starting three phase motors
D) more efficient operation at full load speed

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

A permanent split-capacitor motor has a ____.


A) start and run capacitor
B) start capacitor only
C) run capacitor only
D) split phase capacitor

E) A) and B)
F) None of the above

Correct Answer

verifed

verified

The centrifugal switch mounted on the shaft of a split-phase motor has a normally closed contact.

A) True
B) False

Correct Answer

verifed

verified

The coil of a potential relay has ____________________ resistance.

Correct Answer

verifed

verified

The difference between synchronous speed and full load speed is called ____________________.

Correct Answer

verifed

verified

slip

Start windings are placed ____ with the run windings.


A) 180 degrees out of phase
B) in phase
C) slightly out of phase
D) in series

E) A) and C)
F) B) and C)

Correct Answer

verifed

verified

When not air cooled, the heat generated by the motor in a hermetic motor-compressor assembly is removed by what?

Correct Answer

verifed

verified

It is remo...

View Answer

A split-phase motor that has a current relay and a start capacitor is called a(n) ____ motor.


A) Capacitor Start, Capacitor Run (CSCR)
B) Capacitor Start, Induction Run (CSIR)
C) Induction Start, Induction Run (ISIR)
D) Permanent Split Capacitor (PSC)

E) B) and D)
F) All of the above

Correct Answer

verifed

verified

The rotating portion of an electric motor is called the ____________________.

Correct Answer

verifed

verified

A Capacitor Start Capacitor Run (CSCR) motor that is wired with a potential relay will have the start winding energized when the relay's contacts open.

A) True
B) False

Correct Answer

verifed

verified

When a Capacitor Start Induction Run (CSIR) motor is running and up to speed, what is the total capacitance acting on the motor? (Assume the run capacitor is 5 microfarads and the start capacitor is 20 microfarads, if present.)


A) 4 microfarads
B) 5 microfarads
C) 20 microfarads
D) 25 microfarads

E) A) and D)
F) B) and C)

Correct Answer

verifed

verified

Once the start winding and the start capacitor have been removed for the circuit, the motor will continue to operate with only the run winding energized.

A) True
B) False

Correct Answer

verifed

verified

True

The resistances of the windings in a three phase motor are all equal.

A) True
B) False

Correct Answer

verifed

verified

True

The heavier the load on an operating motor, the greater the amount of slip.

A) True
B) False

Correct Answer

verifed

verified

A motor that has copper bars in the rotor is classified as a(n) ____________________ type.

Correct Answer

verifed

verified

Showing 1 - 20 of 36

Related Exams

Show Answer